Secondary Operator Panel (SOP)

General

The Secondary Operator Panels (SOPs) is an operator interface for controlling the equipment within the 2V02 Underbody Structure Cell.

SOPs allow for personnel to control, adjust or view the status of the equipment within one of the four zones in the 2V02 Underbody Structure Cell. The zone controlling panel features a Siemens Simatic touch screen display as well as three buttons to place the zone's equipment into the work position (green button), zone’s equipment to the home position (yellow button), or initiate automatic mode (white illuminated button).

For more information regarding the layout of components and electrical connections for the SOP, refer to pages 553-554 of the Wiring Diagram (WD): 2V02&EFS_EL .

Major Components

The Secondary Operator Panel (SOP) receives 24VDC power that is wired above the Main Electrical Disconnect switch on the specific zone PDP. If the Main Electrical Disconnect Switch is placed into the Off position, the SOP will stop running.

Item Description Part Number:
A Siemens ProfiNet Module 6ES7193-6AR00-0AA0
B Siemens Digital Input Module 6ES7131-6BH01-0BA0
C Siemens Digital Output Module 6ES7132-6BH01-0BA0
D Siemens SIMATIC DP, Electronic Module (x2) 6ES7136-6BA01-0CA0
E ABB 5 AMP Miniature Circuit Breaker (x2) 2CDS200914R0001
SOP Major Components